site stats

Too many pgs per osd 320 max 250

Web6. máj 2015 · If we should shoot for 300 PGs per OSD, then it seems like we should use a pg_num of 16, since even 32 would result in more than 300 per OSD. However, if this … Web27. jan 2024 · root@pve8:/etc/pve/priv# ceph -s cluster: id: 856cb359-a991-46b3-9468-a057d3e78d7c health: HEALTH_WARN 1 osds down 1 host (3 osds) down 5 pool(s) have no replicas configured Reduced data availability: 236 pgs inactive Degraded data redundancy: 334547/2964667 objects degraded (11.284%), 288 pgs degraded, 288 pgs undersized 3 …

Ceph too many pgs per osd: all you need to know · GitHub - Gist

Web18. júl 2024 · pools: 10 (created by rados) pgs per pool: 128 (recommended in docs) osds: 4 (2 per site) 10 * 128 / 4 = 320 pgs per osd. This ~320 could be a number of pgs per osd … Webcluster is still complaining TOO_MANY_PGS too many PGs per OSD (262 > max 250) I have restarted ceph.target services on monitor/manager server What else has to be done to have the cluster using the new value ? Steven. c***@jack.fr.eu.org 2024-10-31 … randy kleen obituary el paso il https://holistichealersgroup.com

ceph分布式存储-常见 PG 故障处理 - 掘金 - 稀土掘金

Web30. mar 2024 · Get this message: Reduced data availability: 2 pgs inactive, 2 pgs down pg 1.3a is down, acting [11,9,10] pg 1.23a is down, acting [11,9,10] (This 11,9,10 it's the 2 TB SAS HDD) And too many PGs per OSD (571 > max 250) I already tried decrease the number of PG to 256 ceph osd pool set VMS pg_num 256 but it seem no effect att all: ceph osd … Web11. júl 2024 · 1、登录,确认sortbitwise是enabled状态: [root@idcv-ceph0 yum.repos.d]# ceph osd set sortbitwise set sortbitwise 2、设置noout标志,告诉Ceph不要重新去做集群的负载均衡,虽然这是可选项,但是建议设置一下,避免每次停止节点的时候,Ceph就尝试通过复制数据到其他可用节点来重新平衡集群。 [root@idcv-ceph0 yum.repos.d]# ceph osd … Web15. okt 2016 · health HEALTH_WARN 3 near full osd(s) too many PGs per OSD (2168 > max 300) pool default.rgw.buckets.data has many more objects per pg than average (too few pgs?) 从我所收集网上,这会不会造成我的具体问题。但我对Ceph是新手,可能是错的。 我有一个星期三和三个OSD。这只是为了测试。 randy kittleson

解决too many PGs per OSD的问题 - CSDN博客

Category:ceph -s集群报错too many PGs per OSD - CSDN博客

Tags:Too many pgs per osd 320 max 250

Too many pgs per osd 320 max 250

Placement Groups — Ceph Documentation

Web25. mar 2024 · As a workaround, the max PGs per OSD (default is 250) can be increased from the toolbox with the following command: ceph config set mon … Web4. mar 2016 · ceph-s查看集群状态出现下面的错误 too many PGs pre OSD (512 > max 500) 解决方法: 在/etc/ceph/ceph.conf中有个调整此项警告的阈值 $ vi /etc/ceph/ceph.conf …

Too many pgs per osd 320 max 250

Did you know?

Web10 * 128 /4 = 320 pgs per osd. Ce ~320 pourrait être un certain nombre de pgs par osd sur mon cluster. Mais ceph pourrait distribuer ces différemment. Ce qui est exactement ce qui se passe et est sur le 256 max par osd indiqué ci-dessus. Mon cluster HEALTH WARN est HEALTH_WARN too many PGs per OSD (368 > max 300). Web1 You can use the Ceph pg calc tool. It will help you to calculate the right amount of pgs for your cluster. My opinion is, that exactly this causes your issue. You can see that you should have only 256 pgs total. Just recreate the pool ( !BE CAREFUL: THIS REMOVES ALL YOUR DATA STORED IN THIS POOL! ):

Webroot@pmox1:~# ceph status cluster: id: 2b45cd07-668d-49da-91eb-ee8d1dd41883 health: HEALTH_WARN Degraded data redundancy: 22/66 objects degraded (33.333%), 13 pgs degraded, 288 pgs undersized OSD count 2 < osd_pool_default_size 3 too many PGs per OSD (288 > max 250) services: mon: 1 daemons, quorum pmox1 (age 25m) mgr: … WebIf you receive a Too Many PGs per OSD message after running ceph status, it means that the mon_pg_warn_max_per_osd value (300 by default) was exceeded. This value is compared …

Web9. okt 2024 · Now you have 25 OSDs : each OSD has 4096 X 3 (replicas) / 25 = 491 PGs The warning you see is because the upper limit is 300 PGs per OSD, this is why you see the warning. Your cluster will work but it puts too much stress on the OSD as it needs to synchronize all these with other peer OSDs. Web17. mar 2024 · 分析 问题原因是集群osd 数量较少,在我的测试过程中,由于搭建rgw网关、和OpenStack集成等,创建了大量的pool,每个pool要占用一些pg , ceph 集群默认每块 …

Web30. nov 2024 · ceph OSD 故障记录. 故障发生时间: 2015-11-05 20.30 故障解决时间: 2015-11-05 20:52:33 故障现象: 由于 hh-yun-ceph-cinder016-128056.vclound.com 硬盘故障, 导致 ceph 集群产生异常报警 故障处理: ceph 集群自动进行数据迁移, 没有产生数据丢失, 待 IDC 同.

Web23. sep 2024 · This is the current ceph status: root@ld3955:~# ceph -s cluster: id: 6b1b5117-6e08-4843-93d6-2da3cf8a6bae health: HEALTH_ERR 1 MDSs report slow metadata IOs 78 nearfull osd(s) 1 pool(s) nearfull Reduced data availability: 2 pgs inactive, 2 pgs peering Degraded data redundancy: 304136/153251211 objects degraded (0.198%), … randy kiteboarding at windmill ptWeb5. jan 2024 · 修复步骤为: 1.修改ceph.conf文件,将mon_max_pg_per_osd设置一个值,注意mon_max_pg_per_osd放在 [global]下 2.将修改push到集群中其他节点,命令: ceph … randy kirkham law officeWeb18. júl 2024 · pgs per pool: 128 (recommended in docs) osds: 4 (2 per site) 10 * 128 / 4 = 320 pgs per osd This ~320 could be a number of pgs per osd on my cluster. But ceph might distribute these differently. Which is exactly what's happening and is way over the 256 max per osd stated above. randy klatt westcoreWeb28. feb 2024 · 准备机器,osd节点机器需要两个硬盘,配置4GiB/4vCPU/60G x2 监控节点: monitor1:192.168.85.128 monitor2:192.168.85.130 monitor3:192.168.85.131 osd节点: osd1:192.168.85.133 osd2:192.168.85.134 初始化机器 1.修改主机名 在monitor1上操作: hostnamectl set-hostname monitor1 1. 在monitor2上操作: hostnamectl set … randy kittleson podiatry madison wiWeb16. mar 2024 · PG的数量 没有固定的规定一个PG是多大,要有多少个PG。 PG会耗费CPU与内存,如果太多PG会消耗大量的CPU与内存。 但是太少了的话,每个PG中对应的数据就多,数据定位相对就慢,数据恢复也会慢。 创建Pool的时候需要指定PG数量。 Pool的PG数量以后也可以修改,只是会重新均衡Pool中的数据。 无论怎么计算PG数量,一定需要是2 … ovid young obituaryovid young sheet musicWeb2. sep 2014 · The number of placement groups (pgp) is based on 100 x the number of OSD’s / the number of replicas we want to maintain. I want 3 copies of the data (so if a server fails no data is lost), so 3 x 100 / 3 = 100. ovid you can learn from anyone